Metrolog XG10 Release Notes
Visit
our Web Site : www.metrologic.fr
Send us an E-mail : metrologic@metrologic.fr
Important: the functionalities marked
with
are software options. Check the option(s) you need with the tool tip
on the mark.
- Automatic scale values according to
deviations for color mapping scale.
- New color scale configuration and parameters.
- Possibility
to setup the temperature sensor and to set a rotary table inside the
setup assistant.

- Modification of the
21-parameters compensation into 23-parameters compensation.

- Support of multi-selection in one construction activity.

- New
probe radius compensation mode depending on the CAD direction.

- Algorithm
optimization for the feature computing performance.
- Automatic surface point
measurement: ability to measure surface points to inspect the edge of
a surface with relative probing point management (relative to point,
line or plane).
- Ability
to use planes with Point by offset construction.
- New method to define a
line (by position, direction, length and possibly a normal to the
projection plane).

- New
probing strategy for geometrical point (space, angle, corner).

- Ball
center automatic compensation during geometric point measurement.

- Global
Magic Stick: find the nearest feature to measure / to extract from the
current probe position.
- New
measurement mode: possibility to measure a point as a sphere fit with
or without limit point in scan block.
- Start
a scan block from a stable probing to avoid the press F7 key.

- Possibility to use axial features in the origin setup for the Geometrical
alignment.
- New
alignment based on features with measurement wizard for quick fit
alignment.

- Best
fit alignment enhancement: based on tolerance feature only for
point.
- Best
fit alignment enhancement: use tolerances values with same sign
inside constraint criteria.
- Possibility
to associate a picture in the stickers of the features used in the
last RPS Alignment.

- Point cloud import: Rasterized-AC files are now supported.
- When moving the mouse on
a point cloud, visualization of point coordinates and possibility to
extract it as a surface point.

- Advanced
print activity with filter / order / assign alignment capacity.

- Possibility
to change alignment expression when exporting files.


- Improvement
of the QDAS export.

- Evaluate tolerance
user interface improvement.


- Support of datum target
with offset with the advanced tolerance function.

- Print
the probes file during part program activity.
- Display
in the error message the value of the feature form fault when it
exceeds maximum value.
- Possibility to modify the
measurement mode of a surface points group: point to point or
continuous mode (only with SIP and ME5008).
- Support of the ROTSET command.
- Support of the TRANS command.
- Improvement
of the RMEAS command for 2D feature measurement.
- Support
of the CONSTBF command.
- Automatic calibration of
an optical sensor on a probe head if this configuration has been
previously created or if the head has been qualified with 4 positions.

- Improvement of the
optical sensor positioning on sphere before calibration.
- Auto scrolling of the 3D
view on the current scan.
- Possibility to adapt the
optical sensor movement during an acquisition (only with ME5008).

- On portable measuring
device with optical sensor, one touch on the acquisition button starts
the scan and another touch on this same button stops it.
- New Metrologic ME533 manual counting board.
- New
API laser tracker interface via DI driver.

- Handyscan supported.

- Continuous calibration with Metris XC.

- Perceptron V4/V5 interface via Scan works.

- Optotrak + Steinbischler + hard probe via TScanPlus.

- New Kreon Toolkit interface to support Aquilon system
. 
- Add new Unlock/Lock Head
command. This command can be added in the stylus/tools changer
procedures (only with ME5008).

- Ability to reset scales on
the reference marks with an offset (which can be different on each
axis).

- Catia V5 import
improvement : best tolerances management.

- Possibility to define the
angles A and B of a probe head orientation by clicking directly on a
CAD surface or on a feature.

- Improvement of PRD import.

- Improvement of EMB import:
management of design variants.

- Improvement of CATIA V5 file
import: taking account of the unilateral criterion ofor geometric
tolerances of the line and surface profiles.

New export format: TSV export.
In DMIS, improvement of the advanced tolerance function management
:
support of the composite tolerance with the TOL/CPROF
command
support of the command allowing to construct the
point on the top of a cone, with the CONST/VERTEX command
Addition
of t he Offset according to normal function in the
geometric point definition window.

- Addition
of alignment creation date in their properties window.

- Addition
of preview of translation and
rotation values during creation of an alignment
information.

- Support
of new romer NCA arm via driver RDS.

Top of page
Summary
|